"FATAL ERROR : An unexpected condition occurred in file [/export/home/build_root/861HotFix_build/powrmart/server/dwriter/wrtxml/wrtdom.cpp] line [4385]. Aborting the DTM process" when a PowerCenter session fails
Problem Description

A PowerCenter session fails with the following error: 

********** FATAL ERROR : An unexpected condition occurred in file [/export/home/build_root/861HotFix_build/powrmart/server/dwriter/wrtxml/wrtdom.cpp] line [4385].  Aborting the DTM process.  Contact Informatica Global Customer Support. ***********  ] 27627].

Cause
This issue occurs when the primary key is Null from the XML generator. The XML generator generates the XML for the input passed.
Solution

To resolve this issue, create a filter to filter out Null from going to the XML generator by doing the following:

  1. In the Filter, CHECK ThE out_GK_v_ContactMechMSC IS notnull.
  2. Similary, check for all the Primary key ports connected to all the Groups.
More Information

The following is the log:

pmdtm(_ZN23STransformationRunnable13processOneBlkEv+0x35d)[0x838d909]
pmdtm(_ZN23STransformationRunnable3runEv+0x12b)[0x838e217]
pmdtm(_ZN23STransformationRunnable13handleRequestERK15SManagerRequest+0x4d)[0x838e385]
pmdtm(_ZN7SWorker3runEv+0x2c1)[0x820ebdd]
pmdtm(_ZN12SDTMRunnable14MainEntryPointEv+0xd0)[0x81e98d4]
/informatica/powercenter/products/8.6.1/server/bin/libpmcef.so(_Z5runitPv+0x1d)[0xb7f092dd]
/lib/libpthread.so.0[0xb7f132ab]
/lib/libc.so.6(__clone+0x5e)[0xb497fb9e]

2011-01-07 02:27:45 : INFO : (28773 | 2769247136) : (IS | IntSvcProd) : node01_txiappls601 : CMN_1954 : [:Session task instance [s_CCSTAGE_to_CDH_PFDLRALL_OrgCustomer]:] Process id 27627. Standard output and error:
0x14)[0x951f26ac]
/informatica/powercenter/products/8.6.1/server/bin/libpmmidxmlwrt.so(_ZN16PMidWrtPartition15eofNotificationEPK16RTMgepInputGroup+0x1e)[0x9521de46]
/informatica/powercenter/products/8.6.1/server/bin/libpmmidxmlwrt.so(_Z9notifyEofP14PMgepPartitionPK16RTMgepInputGroup+0x2d)[0x95208681]
/informatica/powercenter/products/8.6.1/server/bin/libpmmidxmlwrt.so(_Z15eofNotificationP24infa_ct_partition_structP25infa_ct_inputgroup_struct+0x22)[0x952086da]
pmdtm(_ZN11SMGEPWidget9HandleEofEj+0xfc)[0x844dbe8]
pmdtm(_ZN7SWidget3EofEjj+0x144)[0x8406838]
pmdtm(_ZN7SWidget3EofEjj+0x3ff)[0x8406af3]
pmdtm(_ZN7SWidget3EofEjj+0x3ff)[0x8406af3]
pmdtm(_ZN7SWidget3EofEjj+0x3ff)[0x8406af3]
pmdtm(_ZN7SWidget3EofEjj+0x3ff)[0x8406af3]
pmdtm(_ZN7SWidget3EofEjj+0x3ff)[0x8406af3]
pmdtm(_ZN7SWidget3EofEjj+0x3ff)[0x8406af3]
pmdtm(_ZN7SWidget3EofEjj+0x3ff)[0x8406af3]
pmdtm(_ZN14SAggWidgetBase3EofEjj+0x11f)[0x83f36a3]
pmdtm(_ZN7SWidget3EofEjj+0x3ff)[0x8406af3]
pmdtm(_ZN19TLeafExchangeWidget11PushSegmentEPPS_jjRj+0x8e4)[0x83b7664]

Applies To
Product: PowerCenter
Problem Type:
User Type: Administrator
Project Phase:
Product Version: PowerCenter Advanced Edition 8.6; PowerCenter Advanced Edition 8.6.1
Database:
Operating System:
Other Software:

Reference
Attachments
Last Modified Date:3/28/2012 10:48 PMID:124313