Error while restoring PowerCenter repository content
Problem Description
While restoring repository from Informatica Administrator, the following error pops up:

   reperr.jpg
​​
Cause
On reviewing the repository service logs, the following error is observed:

REP_62301: A versioned repository cannot be started or restored without a team-based development license key.

To restore a versioned repository, team based development license is required, without which the above error is displayed.

Solution
​Create a case with GCS Shipping team to acquire a license to include team based license option (verify in Informatica Administrator->license->options->service options->look for "Team Based Development" as description).

  1. If the license is incremented with "Team Based Development" option, repository service with existing key can be used to restore the content.
  2. If a new license is acquired, perform the following steps to restore the content:
    1. Disable the repository service.
    2. Click on old license->assigned services->edit->remove the repository service from the list.
    3. Click on new license->assigned services->edit->add the repository service from the list.
    4. Enable the repository service.
    5. Restore the content now.
More Information
Applies To
Product: PowerCenter; Data Quality
Problem Type: Configuration
User Type: Administrator
Project Phase: Configure
Product Version: Informatica 9.x; Informatica 10.x
Database:
Operating System:
Other Software:

Reference
Attachments
Last Modified Date:8/19/2019 6:14 AMID:495857
People who viewed this also viewed

Feedback

Did this KB document help you?



What can we do to improve this information (2000 or fewer characters)