ERROR: "[21 Nov 2017 14:39:44,923][main][FATAL][] [BootstrapNodeAgent] Port parameter should be more than 1024
java.lang.NumberFormatException: For input string: "null"
Problem Description
The following error is displayed in nodeagent.log while starting the PMPC through Solutions.sh script:

    [21 Nov 2017 14:39:44,923][main][FATAL][] [BootstrapNodeAgent] Port parameter should be more than 1024
    java.lang.NumberFormatException: For input string: "null"
        at java.lang.NumberFormatException.forInputString(NumberFormatException.java:65)
        at java.lang.Integer.parseInt(Integer.java:580)
        at java.lang.Integer.parseInt(Integer.java:615)
        at com.informatica.cep.nodeagent.bootstrap.BootstrapNodeAgent.main(BootstrapNodeAgent.java:122)
    [21 Nov 2017 15:09:38,619][main][FATAL][] [BootstrapNodeAgent] Port parameter should be more than 1024
    java.lang.NumberFormatException: For input string: "null"
        at java.lang.NumberFormatException.forInputString(NumberFormatException.java:65)
        at java.lang.Integer.parseInt(Integer.java:580)
        at java.lang.Integer.parseInt(Integer.java:615)
        at com.informatica.cep.nodeagent.bootstrap.BootstrapNodeAgent.main(BootstrapNodeAgent.java:122)
​​
Cause
​This issue occurs when hostagent.ip and hosagent.port entry is missing because of which zombie process is getting triggered.
Solution
  1. Edit <PMPC_HOME>/bin/conf/solution.properties and add the following two entries at the bottom.

    (Note 10.118.192.132 is the IP address of the PMPC server, change if the one below is not correct)
    hostagent.ip=<IP_ADDRESS>
    hostagemt.port=<Port number>
  2. Shutdown all service and make sure no zombie PMPC process is running.
    Note carefully because logs have the following which shows a zombie process causing start up failure.

    [21 Nov 2017 11:09:48,647][main][FATAL][] [BootstrapNodeAgent] Failed to start the process.
    java.lang.Exception: An instance of host agent is already running on same port.
  3. Services should now start up fine with solutions.sh start.
For more information, refer to KB 504805.
More Information
Applies To
Product: Complex Event Processing
Problem Type: Configuration
User Type: Administrator
Project Phase: Configure
Product Version: Proactive Monitoring for PowerCenter Operations and PowerCenter Governance 3.0
Database:
Operating System:
Other Software:

Reference
Attachments
Last Modified Date:9/16/2019 11:38 PMID:524616
People who viewed this also viewed

Feedback

Did this KB document help you?



What can we do to improve this information (2000 or fewer characters)