ERROR: "PWX-02200 Incorrect environment for DL1 execution. Check NETPORT for server job or executable for client." while running a profiling jobs for IMS segments
Problem Description
While running a profiling job for IMS segments failed with the following error:

2018-11-14 09:35:54 <DTM-pool-2-thread-5> SEVERE: [LDTM_0072] RR_4035 SQL Error [ 
[Informatica][SCLI PWX Driver] PWX-00271 DBAPI Error. DB_READ failed for file <Non-relational source>. 
[Informatica][SCLI PWX Driver] PWX-01266 DBNTC Receive READ header for file <Non-relational source> failed, rcs 260/2011/2200. 
[Informatica][SCLI PWX Driver] PWX-02011 SQL fetch error. SQLCODE = 2200. 
[Informatica][SCLI PWX Driver] PWX-02200 Incorrect environment for DL1 execution. 
Check NETPORT for server job or executable for client. 
[Informatica][SCLI PWX Driver] PWX-07514 Read call for table met a permanent error. Return codes 271 1266 0. 
Database driver error... 
Function Name : Fetch 
Cause
This issue occurs because the Listener port was not provided for the Location.
Solution
To resolve this issue, for the Location, provide the Netport node name.
More Information
Applies To
Product: Test Data Management; PowerExchange
Problem Type: Configuration
User Type: Administrator
Project Phase: Configure
Product Version:
Database:
Operating System:
Other Software:

Reference
Attachments
Last Modified Date:6/5/2019 10:49 PMID:563390
People who viewed this also viewed

Feedback

Did this KB document help you?



What can we do to improve this information (2000 or fewer characters)