ERROR: "IDR-009003 E An OTL exception occurred when initializing the DBSelector class. Thread ID: xxxx" while running Initial Sync in IDR
Problem Description

In Informatica Data Replication (IDR), while running initial sync, the following error is displayed:


2018-12-03 12:28:07.609 (C65B6D00) IDR-009003 E An OTL exception occurred when initializing the DBSelector class. Thread ID: xxxx.

2018-12-03 12:28:07.609 (C65B6D00) IDR-009002 E The following error occurred when working with the database: Error while trying to retrieve text for error ORA-12705

                                                

                                                SQL statement: 

                                                Additional info: 

                                                Error code: 12705

Cause

This issue might occur when the ORACLE_HOME environment variable is not defined correctly.

Solution
To resolve this issue, set the ORACLE_HOME environment variable to point to the installation directory of Oracle.