Alerts do not populate in the PMPC console reports tab and it is not showing any data in CEP
Problem Description
In Complex Event Processing (CEP), after the installation of PMPC, the PMPC workflow configuration runs as expected, however, it does not process any data. The workflow runs successfully at the scheduled time, however, no row loaded in the PMPC tables PC_COMPLETED_SESSION_R PC_COMPLETED_WORKFLOWS_R.
Cause
​This issue occurs when the repository name is incorrect and the incorrect repository is measured. This is found after verifying the PMPC repository configuration in the PMPC console.
Solution
​To resolve this issue, update the repository name with the correct name and add folders in monitored folder.  Once the new alerts generate, re-run the workflow.