Unable to change Repository service from exclusive mode to normal mode in PowerCenter
Problem Description
One of the repositories can't be changed from exclusive mode to normal mode after upgrading from 10.1 to 10.2 HF1, hence the integration service cannot be started.​
Cause
​This error might occur if the old SiteKey is not copied to the new server.
Solution
To resolve this issue, do the following:
  • Take a back up of the old SiteKey.
  • Rename the old site key as SiteKey_old 
  • Place it in the new server under $INFA_HOME/isp/config/keys.