ERROR: "PWX-36946 No CDCT restart data available" while running a CDC session in PowerExchange
Problem Description
When starting PowerExchange Express CDC Logger, the following error is displayed:

P​WX-36946 No CDCT restart data available
Cause
​This issue occurs when the Logger could not locate the CDCT files which contains condense file restart information.
Solution
This issue occurs when there is no CAPT_PATH parameter defined in the Logger's dbmover.cfg file to identify the directory location of the CDCT files.

To resolve this issue, define the CAPT_PATH parameter in the config file before restarting the Logger.