ERROR: Search File Archive - Drilldown is not coming for the driving table in the tech view pop-up in Data Archive
Problem Description
The driving table is part of the two entities, in one entity it is a child table but in the other entity, it is a driving table. While displaying the results, we are executing the query to get the entities which has this table, when this entity order is the same as the given order then the issue occurs, that is, the drill-down will not come, it will come only for the driving table.
Cause
​This has been identified as an issue in Data Archive 6.4.4
Solution
​​There is an EBF available for this issue.


EBF for ILM Data Archive

 

EBF No

EBF- 17917

Issue(s):

DA-8392: Search File Archive - Drilldown is not coming for the driving table in the techview pop-up

 

Known Limitations

NA

Pre-Requisites for Installation

Ensure that latest DA release is 6.4.4

Steps to Apply EBF

Data Archive

Stop ILM Application Server

Delete the patches applied (delete com folder in <ILM_LOCATION>\webapp\WEB-INF\classes) if any

Delete all files and directories under work directory (where ILM is installed)

Unzip and install  Informatica_ILM_EBF_17917_6.4.4.zip

Start ILM Application Server

EBF Location

/updates/ILM/Oracle+/EBF/6.4.4/EBF17917

ILM EBF Register Updated

Yes

ILM EBF Register

/updates/ILM/EBF/ILM_EBF_Register.xls

More Information
Applies To
Product: Data Archive
Problem Type: Configuration
User Type: Administrator
Project Phase: Configure
Product Version: Data Archive 6.4.4
Database:
Operating System:
Other Software:

Reference
Attachments
Last Modified Date:8/13/2020 10:02 PMID:628039
People who viewed this also viewed

Feedback

Did this KB document help you?



What can we do to improve this information (2000 or fewer characters)